Manual Part No: 930087-01 SNORKEL Gas Convection Oven - 28 –
Manual Rev No: 1
Service and Maintenance (cont.)
Fault Finding
Mains on Indicator Lamp Not Glowing
Check the 10amp circuit breaker to see if it has tripped - before resetting look for the cause.
Oven Switched On, Pilot Will Not Light and No Spark At Electrodes
Check the Auxiliary Fan Switch position. Check the fan rotation and direction. Should be clockwise
viewed from the front of the oven.
Check that the pilot solenoid valve is operating and that gas is flowing to the pilots.
Check the 1 amp fuse, located on the underside of the Pactrol Control. If the fuse has blown check the
solenoid valves for a short circuit.
Check the operation of the Air-Pressure Switch. Note, with fan
NOT rotating - look for continuity
between the common and normally closed contacts. With the fan rotating - look for continuity between
common and normally open contacts. Check the electrode spark gap is 3 – 4 mm and also inspect the
condition of the leads, connectors and porcelain pots, Check the spark ignition generator mounted
behind the lower front panel. Note that the Pactrol Control is supplying 240V live to the Spark Generator
for a short period of time at the start-up. If the Pactrol Control is
NOT supplying this voltage then check
that the Air-Proving relay is operating - it will click in & out when the oven on/off switch is operated.
(The Air-Proving relay is mounted in a box on the rear of the oven).
Pilots Light but Will Not Stay In
Check the gap between the electrode and the pilot body. Check that the leads and connections are
sound. Look at the electrode porcelain pot for cracks etc; Note if one pilot is faulty the Pactrol Control
will lockout. Check that the pilot flame is satisfactory i.e. not lifting, yellow tipping or even too small.
(Clean and adjust as required).
Pilots Satisfactory but Main Burners Will Not Light
Check that the main gas solenoid valve is operating. Check that the oven thermostat is operating and
check for continuity between the thermostat contacts. Check that the Load Control is operating.
Vedere la pagina 27